Model No.︰0.008-0.003
Brand Name︰Qingdao Partner
Country of Origin︰China
Unit Price︰CNY ¥ 100 / pc
Minimum Order︰10 pc
Vacuum insulation panels (VIP for short)
vacuum insulation panels (VIP for short), originated from space technology, Environmentally friendly, high efficiency, energy saving, currently the most advanced efficient thermal insulation material in the world.
Specification and dimension
Common size(L×W×H)
|
Enveloping film types
|
600×400×10 |
Aluminum foil film or glass fiber film
|
600×400×15 |
|
600×400×20 |
|
600×400×30 |
|
600×200×10 |
|
600×200×15 |
|
600×200×20 |
|
600×200×30 |
(Note: if panels size is not fit for bigger area, double layer overlying way can be applied.)
Material composition
The core material is Nano-grade fumed silica reinforced inorganic fiber, and added Aerogel, activation factors and other necessary ingredients.
The high barrier film is composted by PE films, aluminum foils and glass fiber layers.
Application fields
High-end devices, electric appliance fireproofing and insulation,
refrigerators, freezers and other household appliances industry,
reefer containers and cold storage system, integrated housing and building walls.
Heat preservation principle
Heat transfer mechanisms: conduction, convection and radiation.
Influencing factors: air and moisture.
VIP insulation principle
Vacuum insulation: maximize internal vacuum degree and completely cut off air convection.
Conduction blocking: Nano-grade fumed silica with high thermal resistance ability can reduce heat conduction effectively.
Reflection absorption: aluminum foil material for the surface can reflect heat radiation, honeycomb structure of Nano-grade silica can absorb heat reflection.
Moisture-proof and seepage-proof: high barrier film can isolate air infiltration and moisture accumulation.
Efficiency comparison
Insulation material |
VIP |
Mineral wool |
EPS |
XPS |
PU |
Thermal conductivity(W/m.k) |
≤0.008 |
≤0.045 |
≤0.041 |
≤0.030 |
≤0.024 |
Material thickness(mm) |
10-15 |
90 |
80 |
60 |
40 |
Water absorption |
0 |
>5.0 |
<1.0 |
<1.0 |
<4.0 |
Fireproofing grade |
A1 |
A1 |
B1/B2 |
B1/B2 |
B2 |
(Note: if VIP is in damaged condition, the thermal conductivity of bare core panel is around 0.017W/m.k)
Function superiority
Payment Terms︰ TT